S Type LCS-S3 -1kN-200kN Load Cell-Tension and Pressure
Introduction
1. High accuracy, reliability, and stability
2. Tension or pressure
3. Installing easily, and good interchangeability
4. Wide measurement range, and safety-overland function
5. Applied to batcher scale, crane scale, packing scale and so on
6. Optional measurement range: 1kN - 200kN (approximate 100kg - 20t)
Technical Data
Product Decription | |
Material | Alloy Steel or Stainless Steel |
Rated Load(kN) | 1/2/2.5/3/5/7.5/10/15/20/30/50/75/100/150/200 |
Performance | |
Overall Precision | 0.02(linearity+ hysteresis+ repeatability) |
Sensitivity | 2.0mV/V |
Excitation Voltage | 5-12V DC recommend 10V DC |
Creep(in 30min) | ±0.02%F.S/30min |
Zero Balance | ±1%F.S |
Input Resistance | 380±10Ω |
Output Resistance | 350±3Ω |
Insulation Resistance | ≥5000MΩ |
Working Environment | |
Safety Overload | 150%F.S |
Operation Temperature Range | -20-+65ºC |
Zeor Drift | ±0.02%F.S/10ºC |
Output Drift | ±0.02%F.S/10ºC |
Protection Class | IP65(others)/ IP68(7.5-20t) |
Dimension
Rated Load(kN) | Dimension (Unit: mm, Error: ±1mm) | |||
A | B | C | M | |
1/2/2.5/3/5/7.5 | 80 | 70 | 19 | M12×1.75 |
10/15 | 80 | 70 | 25.4 | M12×1.75 |
20/30/50 | 108 | 92 | 25.4 | M18×1.5 |
75/100 | 178 | 130 | 51 | M30×2 |
150/200 | 190 | 160 | 60 | M39×2 |
Installation and Wiring Diagram
Write your message here and send it to us